Intraocular Foreign Body Detectedby Gonioscopy in the Anterior Chamber Angle
PDF
Cite
Share
Request
Case Report
VOLUME: 43 ISSUE: 4
P: 278 - 281
August 2013

Intraocular Foreign Body Detectedby Gonioscopy in the Anterior Chamber Angle

Turk J Ophthalmol 2013;43(4):278-281
1. Fatih Sultan Mehmet Egitim Ve Arastirma Hastanesi, Göz Hastaliklari, Istanbul, Türkiye
No information available.
No information available
Received Date: 13.07.2012
Accepted Date: 11.10.2012
PDF
Cite
Share
Request

ABSTRACT

45-year-old male patient was referred to our hospital with suspicion of foreign body in the right eye. It was learned that a metal burr entered his right eye 2 days ago. Best-corrected visual acuity in the right eye was 9/10. Biomicroscopic examination showed a 2-mm full-thickness corneal incision in the lower paracentral cornea. Defect on the iris corresponding to the incision line drew our attention. Seidel test was negative. After dilatation, the anterior lens capsule and fundus examinations were performed and were normal. The presence of intraocular foreign body (IOFB) was suspected and it was detected in the lower quadrant of the iridocorneal angle by gonioscopy. Emergency surgery was performed and IOFB was extracted.

Keywords:
Anteriorchamber, gonioscopy, intraocularforeign body, penetratingeyeinjuries